<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-04 06-26-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.4 kHz 24 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
24 kHz 74 kHz 10099 31,9636
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,6 dBr 8,11 dBr 8,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 6:26, 4.01.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (56 dBuV) Max at: 74 kHz MIN: 24 kHz % above 75 kHz: 31,9636 Acquired: 2025/01/04 6:25:23 Total samples: 10099 Equivalent time: 0:08:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,6 dBr MIN: 7,6 dBr AVE: 8,11 dBr % above 10,0 dBr: 0,0 Last value: 8,1 dBr (2025/01/04 6:25:22) Station: 96.90 MHz, signal: 4/5 (56 dBuV) 06:18 06:19 06:20 06:21 06:22 06:23 06:24 06:25 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality